PRODUCT DESCRIPTION
This two component paint is mainly prepared by epoxy resin, curing agent, dispersant, and aggregates depend on requirements. Main advantages of this paint are great resistance of slippery, electrostatic, acid and alkali. Moreover, it also has good resistance to organic solvent, heavy load and abrasion. It combines incredible hardness and bonding power to provide a heavy duty and to be used as topcoat.
Typical Uses:
This product is widely used for a wide range of floors with various levels of mechanical and chemical exposure, such as warehouse, garage, office building and laboratory. What’s more, it also can be used for hospital, electronics factory, food and beverage factory.
Application Guide
● Mixing:
Use the power mixer to mix the main paint evenly, and then as you stir it, you add the hardener until you get to mix well. Generally, if the temperature below 10 ℃, it needs 20 min induction time; if the temperature over 10℃, it needs 15 min induction time.
● Mixing Ratio:
Part A: Part B= 20: 5 (by weight).
● Thinner:
Epoxy paint thinner.
● Airless Spray:
Nozzle tip: 0.015~0.021 inch.
Spray pressure: 15~18 MPa.
Thinner ratio: 0~10% (by weight of paint).
● Brush, Roller::
Recommended for small areas only. Must achieve required thickness.
DRYING SCHEDULE
Substrate temperature | 10 °C | 20 °C | 30 °C |
To touch (1mm) | 4h | 2h | 1h |
To handle (1mm) | 24h | 12h | 6h |
Min. recoating time | 16h | 8h | 4h |
Max. recoating time | 10h | 7h | 5h |
Pot life | 1.5h | 1h | 0.5h |
* Make sure no chalking and other contaminations before recoating. | |||
* Above data for reference only, actual drying time and recoating time is dependent on temperature, dry film thickness, ventilation condition. |
SURFACE TREATMENT
All surface to be coated shall be clean and dry. The surface shall be evaluated and treated according to ISO8504 standard.
Steel: Sanding to Sa2.5 (ISO8501-1:2007). It is acceptable to polish by power tools to meet at least St2.0(ISO8501-1:2007).
Concrete surface treatment:
a. First of all, it is necessary to confirm whether reliable damp-proof facilities are installed below the concrete base. The new concrete or cement base should be cured for at least 28 days, and its moisture content should not exceed 5%. The moisture content of the base should be evaluated by empirical method.
b. The base surface should be clean, solid and pollution-free, such as slurry and paint splashing, curing agent, grease and so on. For excessive float pulp, it is better to first use slight roughing, polishing, oil-stained ground, using electric angle grinder to polish.
c. The cracks and empty drum on the floor surface should be repaired first.
d. Whatever method is used to treat the surface, a clean, solid and dry base surface must be obtained. It is especially important that the grassroots should not be in a state of rising tide.
e. The base layer is cleaned and sanded with a sander.
APPLICATION
Application conditions: Substrate temperature shall be at 3 ℃ higher than dew point, relative humidity less than 85%. Measurement of temperature and humidity should be close to substrate.
CLASSICAL COATING SYSTEM
Please inquiry JIANBANG Paint for specific coating solutions.
Epoxy Sealing Primer: 0.1mm (Thickness)
Epoxy Putty: 1mm (Thickness)
Industrial Functional Epoxy Floor Paint: 0.2mm (Thickness)
SAFETY AND HEALTH
Please refer to MSDS before using this product. If you do not fully understand the restrictions, or cannot follow MSDS directions strictly, do not use this product. This volatile product is flammable. Keep this product away from flame or fire. Smoking is strictly prohibited in working area. Keep working area ventilated during application to make sure solvent vapor content is low in the air. PPE is necessary to avoid this product contacting with eyes or skin. More detailed safety tips are based on practical situation.
Please handle used paint barrel correctly to avoid any pollution.
Storage:
Store this product in shady, dry, and ventilated warehouse. The shelf life is 12 months at room temperature. If exceeding shelf life, the products shall be tested before using.
Disclaimer:
All technical data given in this document is based on our knowledge achieved in lab and practice, it is not completely correct. Although we try to keep the validity of our advice, however we cannot predict the practical conditions that will affect paint quality. Herein, we cannot be responsible for the consequences of variations in such conditions, or for unforeseen conditions. We reserve the right to modify this document without informing in advance.
Packaging | Packing size | Packing weight |
Part A | 20L | 20 KG |
Part B | 6L | 5 KG |
Certificate